Estate capacity & leasing

Understand the lease. Know the services behind it.

Search retail units and kiosk circuits together. Compare boxed lease provisions with coloured base-build service summaries, see clearly explained allowance differences and open source references. Review recommended leasing types, illustrative location plans and draft technical guides. Electrical infrastructure is not live in this sample.

For asset managers · leasing teams · engineers

Interactive demonstration · All units, documents and values below are fictional

Units & kiosks

Search an example unit to compare lease provisions with base-build allowances. Open each coloured service box to see the supporting details, sources and outstanding checks.

DEMO-K1Example kiosk · individual circuitShared-panel supply →
FICTIONAL UNIT RECORD

DEMO-02

Example café B

(Pre-leasing)

Café · All building services

Location & plans

Where this example unit sits

Illustrative estate · Example building · Ground floor · DEMO-02

Estate location schematic
DEMO-02FICTIONAL SCHEMATIC · NOT TO SCALE
Unit layout schematic
DEMO-02Illustrative unit outlineFICTIONAL SCHEMATIC · NOT TO SCALE

New illustrative diagrams only. No real building, lease boundary, address or client drawing is represented.

01 / Leasing guidance

Recommended leasing type

Illustrative recommendation, not an approval of use or service capacity.

  • General retailNo cooking
  • Light F&BAssumes electric cooking only and recirculating extract
  • Full F&BFull gas cooking
02 / Leasing details

Leasing provisions

What the example landlord documents describe.

Download sample technical guide ↗

Fictional demonstration · DRAFT · Not for design or contractual use.

SOURCE · EXAMPLE BASE BUILD DEFINITIONDEMO-02-BBD ↗

View fictional source · opens in a new tab

Revision Example 02 · Fictional · not an issued document

Created for this public demonstration. No real client document is reproduced.

Agreement status: not verified. A BBD describes the landlord’s stated provision; it is not confirmation of an executed lease. Check the signed agreement, technical schedules, variations and handover evidence before relying on a provision.

Lease electrical allowance
90 kVA

Red: lease provision exceeds the recorded base-build allowance. Lease: 90 kVA; base-build: 68 kVA. Fictional comparison, not a verified capacity shortfall.

Proposed use
Café
Chilled water
36 kW
Heating · LTHW
15 kW
Fresh air
450 l/s
Exhaust air
400 l/s
Water
28 mmMetered cold-water connection; tenant to confirm peak demand.
Drainage
Provision recordedFoul drainage connection; grease management and kitchen discharge subject to approval.
Kitchen ventilation
Provision recordedIndicative kitchen extract route reserved; airflow, odour control and discharge approval outstanding.
Gas
Not confirmedNo gas provision confirmed. Any requirement needs a separate feasibility review.
Sprinklers
100 mmFictional connection provision only; tenant modifications require specialist coordination.

Before a leasing decision

Confirm the agreed scope, permitted use, tenant equipment demands, landlord approvals and responsibility for any upgrades. Missing provisions remain unconfirmed.

03 / Technical details

Base build allowance

Example service connections and allowances for this unit.

Select a service to see its details, sources and qualifications. All figures and sources in this example are fictional.

Electrical160 A68 kVARecorded fuse / breaker · allocation or utility capacity, whichever is lowerClick for more information
SOURCE · EXAMPLE TECHNICAL RECORDDEMO-02-ELECTRICAL ↗

View fictional source · opens in a new tab

Revision Example 02 · Fictional · not an issued document

Created for this public demonstration. No real client document is reproduced.

Table allocation
76 kVA
Utility-allowed capacity
68 kVA
Historic peak demand
39 kVA
Example status
Illustrative only
Supply route
TX-B → Board B
Meter identification
No MPAN or site address is included in this public example.

The summary uses the lower of the 76 kVA table allocation and 68 kVA utility capacity. The original BBD allowance of 90 kVA is a separate lease record. Historic demand and fuse size do not establish spare capacity or an entitlement to an upgrade.

Illustrative supply schedule and historic demand summary only. No live feed or verified site survey is connected. Review the installation, upstream loading, protective devices and tenant load schedule before making a decision.

Boosted cold water28 mmExample base-build cold water connectionClick for more information
SOURCE · EXAMPLE TECHNICAL RECORDDEMO-02-CWS ↗

View fictional source · opens in a new tab

Revision Example 02 · Fictional · not an issued document

Created for this public demonstration. No real client document is reproduced.

Example lease provision: Metered cold-water connection; tenant to confirm peak demand.

Connection size does not establish flow, pressure or whether the supply is boosted. Confirm metering, peak demand and the installed connection. Missing data remains unconfirmed.

Chilled water36 kWIllustrative duty · tenant-side connectionClick for more information
SOURCE · EXAMPLE TECHNICAL RECORDDEMO-02-CHW ↗

View fictional source · opens in a new tab

Revision Example 02 · Fictional · not an issued document

Created for this public demonstration. No real client document is reproduced.

Example cooling duty: 36 kW.

Review the connection location, pipe size, flow, tenant-side temperatures, controls and commissioning evidence alongside the BBD and tenant design.

A fictional duty for demonstrating the interface. It does not represent a surveyed installation, measured capacity or confirmed landlord offer.

LTHW15 kWIllustrative heating duty · tenant-side connectionClick for more information
SOURCE · EXAMPLE TECHNICAL RECORDDEMO-02-LTHW ↗

View fictional source · opens in a new tab

Revision Example 02 · Fictional · not an issued document

Created for this public demonstration. No real client document is reproduced.

Example heating duty: 15 kW.

Confirm heat-exchanger duty, flow and return temperatures, pipework, controls and commissioning evidence before comparing available provision with the tenant requirement.

This heating allowance is fictional. A pipe diameter or historic drawing alone would not confirm current heating capacity.

Fresh air450 l/sExample BBD allowance · installation not verifiedClick for more information
SOURCE · EXAMPLE BASE BUILD DEFINITIONDEMO-02-BBD ↗

View fictional source · opens in a new tab

Revision Example 02 · Fictional · not an issued document

Created for this public demonstration. No real client document is reproduced.

Example fresh air allowance: 450 l/s.

Indicative kitchen extract route reserved; airflow, odour control and discharge approval outstanding.

The lease allowance and installed airflow are separate records. Confirm the intake, duct or louvre provision and commissioning results. A fresh air allowance does not establish a kitchen extract approval or permitted use.

Exhaust air400 l/sFictional exhaust allowance · not kitchen-extract approvalClick for more information
SOURCE · EXAMPLE TECHNICAL RECORDDEMO-02-EXHAUST ↗

View fictional source · opens in a new tab

Revision Example 02 · Fictional · not an issued document

Created for this public demonstration. No real client document is reproduced.

Illustrative ventilation record only. Confirm the route, permitted use, odour control and commissioning evidence before relying on an allowance.

Sprinklers100 mmExample base-build connection to the unitClick for more information
SOURCE · EXAMPLE TECHNICAL RECORDDEMO-02-SPRINKLER ↗

View fictional source · opens in a new tab

Revision Example 02 · Fictional · not an issued document

Created for this public demonstration. No real client document is reproduced.

Illustrative landlord connection only. Tenant modifications and fire-alarm interfaces require landlord and specialist coordination.

Connection size does not confirm hazard classification, pressure, design flow, coverage or compliance. Where no size is recorded, obtain the unit-specific drawings and specialist confirmation.

All example records, plans and source pages are fictional. No real client information is included.